This units is used when you want to store your products into a vessel. Put over the image and drag your unit to the main screenwork, using button right of your mouse.
This is list of all storage units that you can use.
When you drag this unit to the main screenwork, that appear. Set the diameter of tank(D), set the height of the tank(H), The Volume will be computed in this way.
Now, select the INOUT TAB. That appear. Each # INOUT called Hn, correspond to each In or Out of the tank, called take. This number is the height(Hn) of each take. By default each take is 12.8% of height of the tank.This number is used to compute the pressure in each take. The Pressure is computed in this way :
In Each iteraction, the pressure of all take are computed, the temperature of the tank is computed, also the composition could be computed if it was necessary. |
When you drag this unit to the main screenwork, that appear. Set the diameter of the tank(D), and set maximum pressure, The volume will be computed in this way
Now, select the INOUT TAB. That appear. Each # INOUT called Hn, correspond to each In or Out of the tank, called take. This number is the height(Hn) of each take. By default each take is 15.9% of the diameter of the tank. This number is used to compute the pressure in each take. The Pressure is computed in this way : |