STAKER - LINE - VALVE - FIC

1. Make click on FILE, on OPEN,and look for "simula3_1b.pca" file, then click OK. check it up all datum are right. Then click in SIMULATION, AND RUN

When you put your pointer of the mouse over the line red, that will appear.

The Flowrate is 1,46 kg/s. You have 2 atm inlet of pipe, to 1atm outlet of 2 pipe of 50ft of 1". Water is the product.

When you put your pointer of the mouse over the valve, that will appear.

The Pressure inlet of the valve is 1.41 and outle is 1.4 atm @ 20 seconds, Valve opening is 88%. This value change because the line is fill with water.

If you see the simulation for long time, you notice the flowrate will be static(0.85kg/s) and the pressure inlet will be 1.79 and outlet 1.21, Valve opening will be 8.4%.


2. Make click on FILE, on OPEN,and look for "simula3_2b.pca" file, then click OK. check it up all datum are right. Then click in SIMULATION, AND RUN

When you put your pointer of the mouse over the line red, that will appear.

The Flowrate is 0.07 kg/s. You have 2 atm inlet of pipe, to 1atm outlet of 2 pipe of 50ft of 1". Propane is the product.

When you put your pointer of the mouse over the valve, that will appear.

The Pressure inlet of the valve is 1.62 and outle is 1.60 atm @ 149 seconds, the valve opening is 87%. This value change because the line is fill with Propane.

If you see the simulation for long time, you notice the flowrate will be static(0.0055kg/s) and the pressure inlet will be 1.75 and outlet 1.40, and the valve opening will be 2%.


BACK